Quality Testing

No matter how reliable the surface of the goods looks, we will conduct a series of tests by ourselves, or entrust a professional third-party testing organization for testing, such as: Solderability test, to prevent oxidation and ensure the reliability of soldering; Marking permanency test,to prevent refurbished parts. X-Ray tests will also come if needed,etc.

You can find out the following procedures to test the sold parts:

Test Performed Free Additional Charge
External Visual Inspection
Solderability Inspection
HCT-Chemical Wipe Inspection
Program Blank Inspection
Functional / Electrical Performance Inspection
XRF-Lead-Free Analysis
X-Ray Inspection
Anatomical Inspection
Detailed Test Report

Definitions (as defined within AS6081):

  • Known Authentic Part(Golden Sample)-A part which has either been purchased directly from the manufacturer, their authorized distributors, or authenticated by the manufacturer with supporting documentation.
  • Unused-Electronic parts that have not been previously used(i.e., attached to a board or powered up since leaving the supply chain). Unused material can contain mixed date codes, lot codes, or countries of origin, and should be received in original factory or third-party packaging. The material may have minor scratches or other physical defects as a result of handling, but the leads should be in good condition and should not be refurbished. The material should be guaranteed to meet the manufacturer’s full specifications. Unused Programmable parts should be received without having been previously programmed.
  • Used(Refurbished or Pulled)-Product that has been electrically charged and subsequently pulled or removed from a socket or other electronic application.Used product may be received in non-standard packaging, and may contain mixed lots, date codes, be from different facilities, etc. Parts may have physical defects such as scratches, slightly been leads, test dots, faded marking, chemical residue or other signs of use, but the lead should be intact.Used product may be sold with a limited warranty, and programmable parts may still contain partial or complete programming which could impact the part’s functionality.
  • Refurbished-Parts that have been renovated to restore them to as like new condition, e.g., leaded parts may have had their leads realigned and re-tinned and subjected to cleaning agents and chemical processing.
  • Counterfeit Parts-A fraudulent part that has been confirmed to be a copy, imitation, or substitute that has been represented,identified, or marked as genuine, and/or altered by a source without legal right.

Report Explanations:

  • “Result” is the condition of devices, per the definitions provided by AS6081(above) with the addition of “Remarked”, which is any device who’s original marking has been replaced.A device could, for example, but Unused but also have been remarked, so the Result would be “Unused/Remarked”.
  • “Risk Factor” is a calculation of the remaining risk of a device being counterfeit or substandard from the result of the processes conducted, and risk associated with not conducting some processes.
  • Minor observations such as scratches and loose contamination from normal handling, packaging, storage and aging are defined and available upon request.
  • “FAR” in the process summary means “Further Analysis Recommend” additional tests to verify an observation found in one process, or gaps in the requested test plan, we will identify those areas of risk as “FAR”.
  • Note that definitions are as defined within the AS6081 standard.

 

Notes and Disclaimers:

  • Product analysis results are applicable for the inspected samples only.
  • Inspection methods are assigned Pass / Fail Criteria based upon JEDEC JES9B manufacturing standard. Military-grade products are inspected to MIL-STD specifications. Observations outside of those tolerances are deemed to make the product unfit for use.
  • Observations defined by IDEA-STD-1010B, AS6081, AS6171 and MYTH expertise and used for comparison purposes to the devices analyzed for this report. “Known-good samples” or “Golden samples” are provided to compare to unverified products.”

Submit your question

If you did not find what you were looking for, please submit your question and we will get back to you

    Translate »